For use with oil, water or any other liquid which will not attack brass or bronze, also suitable for air or inert gases below 25 bar (excluding Oxygen or Acetylene).
Specification
- Diameter: 100 & 160mm
- Ranges: from -1 bar (-30″Hg) vacuum to 1000 bar (15000 psi)
- Accuracy: ±1.0% fsd
- Orientation: Bottom or lower rear
- Connection sizes: 1/4″, 3/8″ & 1/2″ BSP, BSPT or NPT
- Mounting : Direct
- Case filling: Dry
- Case material: 304 stainless steel
- Connection material: Brass
- Window: Instrument glass
- Process temperature: 60°C max
- Weather protection: IP 54
Options
- Custom ranges/dials
- Customer logo
- Increased accuracy of ±0.5% or ±0.6% FSD
- Alternative mounting: Panel mount with clamp, surface mount, 3 hole front flange
- Indicating or max drag pointer
- Bespoke threads
- Rubber shroud
- Electrical contact
Calibration Notes
- Traceable to national standards
- UKAS
If you have any questions, please contact us on +44 (0) 117 965 4615 or visit our enquiry page and submit the form.
We can also customise our products to your specific needs.